CableMod is recalling all 90deg and 180deg 12VHPWR adapters - eviltoast

the nvidia 12VHPWR shitstorm continues!

  • FeelzGoodMan420
    link
    fedilink
    English
    arrow-up
    1
    ·
    11 months ago

    Do you need both a new cable and the updated gpu pcb port to take advantage of this?

    • empireOfLove2@lemmy.dbzer0.comOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      11 months ago

      The primary changes have been to the male pin connector which exists on the GPU or PSU side not the female socket connector which exists on the cable. So the cable is fine but the gpu is not.

      It could likely be replaced on thr GPU by a good repair shop. The PCB plug is a quite easy solder job all things considered.

      • FeelzGoodMan420
        link
        fedilink
        English
        arrow-up
        2
        ·
        11 months ago

        Don’t you have that reversed? Isn’t the cable the male inputs? You have to slot them into the GPU/PSU.

        • empireOfLove2@lemmy.dbzer0.comOP
          link
          fedilink
          English
          arrow-up
          2
          ·
          edit-2
          11 months ago

          well, the plug standard is a bit confusing.

          The “female” mechanical socket on the motherboard contains the MALE electrical contacts. And the “male” mechanical plug on your cable contains the FEMALE electrical contacts. This way they slip inside one another without exposed contacts.
          I was talking about things from the electrical point of view since that’s where the only spec modifications were made.

          Plug/cable end.. note the electrical contacts are hollow tubes (female)
          Socket/PSU or GPU end.. Note the singluar male pins in the holes.

          • FeelzGoodMan420
            link
            fedilink
            English
            arrow-up
            1
            ·
            11 months ago

            Yea that makes sense. Thanks for clarifying. It seems some PSU makers also have new 12v2x6 cables? Are you sure they didn’t change the cable at all?

            • empireOfLove2@lemmy.dbzer0.comOP
              link
              fedilink
              English
              arrow-up
              1
              ·
              11 months ago

              Doesn’t seem to have changed the cable at all, no. The only mechanical changes I can find anywhere, and I’ve looked quite a bit, are strictly to the electrical male pins on the device side to improve contact on the current carriers and shorter sense pins as to prevent operation if the insertion is even a tiny bit incorrect- everything else was kept the same as to maintain mechanical compatibility between the two specs.

              PSU makers rebranding cables as 12V2x6 is probably just a marketing/keeping up with the spec thing. It should also mean that they changed the pins on the PSU side as well for modular power supplies.

              • FeelzGoodMan420
                link
                fedilink
                English
                arrow-up
                2
                ·
                edit-2
                11 months ago

                Gotchya. Yea this entire thing is incredibly confusing and frustrating. This entire standard is a fucking disaster. Whoever designed this bullshit should never work in the industry again. I hope the 12v2x6 tweak is enough to finally get past this so people don’t have to worry about their fucking PCs catching on fire.

              • FeelzGoodMan420
                link
                fedilink
                English
                arrow-up
                1
                ·
                edit-2
                11 months ago

                https://www.techpowerup.com/317127/seasonic-unveils-12v-2x6-12vhpwr-successor-cable-invites-beta-testing

                Hmmm I’m pretty sure the cables are changing too? Otherwise, what actually changed with Seasonic’s new 12v2x6 cable then? Are you sure nothing is changing here? They’re giving these “beta” cables out to people for voluntary testing.

                This doesn’t make any sense…so much conflicting information…what the actual fuck do we need to implement this new standard…